- SOLARWATT Manager
- Commissioning
- Connect devices
Connect devices
Overview of supported devices
Table of contents
Full compatibility | |
With restrictions | |
In release check | |
No compatibility |
Inverter
Fronius
EnergyManager pro | Manager flex | |
---|---|---|
Primo (3.0 - 8.2) | ||
Symo (3.0 - 20.0) | ||
Symo Advanced | ||
ECO | ||
Primo / Symo GEN 24 | ||
Primo / Symo GEN 24 plus [hybrid system] | ||
SMA
EnergyManager pro | Manager flex | |
---|---|---|
Sunny Boy (1.5 -6.0) | ||
Sunny Tripower (3.0 - 10.0) | ||
Sunny Tripower (15000 - 25000) TL | ||
Sunny Tripower (5.0-10.0) -3SE-40 [Hybrid system] | ||
Sunny Tripower X (12 - 25) | ||
Sunny Tripower CORE1 | ||
Sunny Tripower CORE2 |
Sunny Tripower X (12 - 25) | Curtailment (limitation of the feed-in-power) via the SOLARWATT Manager is currently not possible. |
Sunny Tripower CORE1 /2 | The connection of this device type is currently undergoing approval testing. Until these tests have been completed, perfect function on the Manager flex cannot be guaranteed. |
KACO
energyManager pro | Manager flex | |
---|---|---|
blueplanet NX3 M2 (3.0 - 20.0) | ||
blueplanet NX3 M3 (25.0 - 33.0) |
Kostal
EnergyManager pro | Manager flex | |
---|---|---|
PLENTICORE plus (3.0 - 10) | ||
PIKO IQ (3.0 - 10) | ||
PIKO MP plus | ||
PIKO CI | ||
PIKO (12 - 20) | ||
Steca / Kontron Solar
EnergyManager pro | Manager flex | |
---|---|---|
StecaGrid coolcept fleX XL (4213 - 10013) | ||
StecaGrid coolcept fleX (1511 - 3611) | ||
StecaGrid coolcept3 fleX (3213 - 6013) | ||
StecaGrid coolcept fleX (3011 - 5011)_2 | ||
SolBrid |
Huawei
EnergyManager pro | Manager flex | |
---|---|---|
SUN2000 -2/3/3.68/4/4.6/5/6KTL-L1* | ||
SUN2000 -3/4/5/6/8/10KTL-M1 (high-current version)* |
*) Hybrid system with LUNA2000-5/10/15-S0 battery system possible. Additional component required for integration into the energy management system: Smart Dongle WiFi-FE
SUN2000 -2/3/3.68/4/4.6/5/6KTL-L1 | Unknown error; the device cannot be installed under the current Manager flex firmware. The problem is under investigation. |
SolarEdge
EnergyManager pro | Manager flex | |
---|---|---|
SolarEdge |
Restrictions
SolarEdge | Permanent error message in the Installer Center "NoPowerACOutMax" (cannot be acknowledged) |
SolarEdge | Connection problems may occur when using inverter firmware 004.019 and 004.020. The problem is being investigated. The use of an external meter to record the inverter power is recommended. See Incompatible inverters |
Incompatible inverters
The power is recorded via separate power meters or energy meters. Depending on the Manager hardware used, different types of meters can be used for performance recording.
There are also differences in the number of meters that can be configured as generation meters.
Meter type | Number of meters that can be configured as generation meters | |
---|---|---|
EnergyManager pro | Manager flex | |
S0 meter* | 2 | 1 |
Shelly Pro 3EM | unlimited | unlimited |
Shelly 3 EM | cannot be used as a generation meter | unlimited |
Installation instructions can be found under Non-compatible inverters.
Home battery system
SOLARWATT
EnergyManager pro | Manager flex | |
---|---|---|
Battery flex AC-1 | ||
Battery flex backup solo | ||
Battery flex DC | ||
MyReserve Command 25 | ||
MyReserve Command 20.2 | ||
MyReserve 500/800 | ||
VARTA
EnergyManager pro | Manager flex | |
---|---|---|
pulse neo | * | ** |
element S5 backup | * | ** |
Cascade element S5 | * | ** |
Cascade pulse neo | * | ** |
*) Varta Split Core Sensor cannot be used as main meter. The installation of an additional bidirectional meter is required.
**) Varta Split Core Sensor can be used as main meter.
Hybrid systems
The supported hybrid systems are listed under Inverters.
Wallboxes
Keba
EnergyManager pro | Manager flex | |
---|---|---|
KeContact P30 c-series | ||
KeContact P30 x-series | ||
KeContact P30 Dienstwagenwallbox | ||
KeContact P30 PV Edition | ||
KeContact P30 a-Series | ||
KeContact P30 Deutschlandedition |
Webasto
EnergyManager pro | Manager flex | |
---|---|---|
live | LAN (number of devices*: 1) | LAN (Number of devices*: 1) |
next | -- | LAN, WiFi (via router) (number of devices*: 1) |
Alfen
EnergyManager pro | Manager flex | |
---|---|---|
Eve Single (S-line / Pro Line) |
Restrictions
Automatic phase switching function not available when installed on EnergyManager pro.
Possible number of actively controlled wallboxes in the energy management system
EnergyManager pro | SOLARWATT Manager flex | |
---|---|---|
Keba | 1 | 3 |
Webasto (Live/Next) | 1 | 1 |
Alfen | 1 | 3 |
Shelly devices
Possible applications
The various Shelly device types can perform a wide range of tasks in the SOLARWATT energy management system:
Network | Possible applications | ||
---|---|---|---|
EnergyManager pro | Manager flex | ||
3EM | WIFI |
|
|
Pro 3EM | WIFI LAN |
|
|
Pro 3EM 400 | WIFI LAN |
|
|
EM | WIFI |
|
|
Per 1PM Pro 2PM Pro 4PM | WIFI LAN |
|
|
Plus1PM Plus2PM | WIFI |
|
|
Plus Plug S Plug S | WIFI |
|
|
Shelly 2.5 | WIFI |
|
|
Main meter: Use as bidirectional meter
Energy meter: Use as single-directional meter
Network interface and installation location
shelly device | network interface | installation location |
---|---|---|
3EM | WIFI | Switch cabinet |
Pro 3EM | WIFI LAN | Switch cabinet |
Pro 1PM Pro 2PM Pro 4PM | WIFI LAN | Switch cabinet |
Plus 1PM Plus 2PM | WIFI | Flush-mounted socket |
Plus Plug S Plug S | WIFI | Schuko socket outlet |
Shelly 2.5 | WIFI | Flush-mounted socket |
Heating solutions
EnergyManager pro | Manager flex | |
---|---|---|
Heat pump via SG Ready interface | * | * |
Stiebel Eltron heat pump Supported types:
| ||
EGO Smart Heater | ||
my-PV AC ELWA 2 | ||
my-PV AC THOR 9s |
*) Connection via Shelly 3EM.
Energy meter / main meter
Manager flex
Meter types that can be used with the SOLARWATT Manager flex:
Interface | Possible applications | |
---|---|---|
S0 meter* | S0 |
|
SOLARWATT AC-Sensor | Ethernet via |
|
Shelly devices** | Ethernet / WiFi |
|
*) A total of up to 2 S0 meters can be connected. For more information, see the S0 counter section at the bottom of this page.
**) See section Shelly devices.
EnergyManager pro
Meter types that can be used with the SOLARWATT EnergyManager pro:
Interface | Possible applications | |
---|---|---|
S0 meter* | S0 |
|
SOLARWATT AC-Sensor |
|
|
Shelly devices** | Ethernet / WiFi |
|
Janitza UMG 103-CBM | RS485 |
|
ABB B23 | RS485 |
|
*) A total of up to 2 S0 meters can be connected (without digital extension). For more information, see section S0 meters at the bottom of this page.
***) See section Shelly devices.
S0 meters
S0 meters are electrical energy meters that transmit their meter readings via electrical pulses.
Meters that deliver pulses in accordance with EN62053-31 can be connected to the SOLARWATT Manager.
The meters are connected directly, i.e. to the S0 inputs of the SOLARWATT Manager.
Possible applications
Possible applications | ||
---|---|---|
EnergyManager pro | Manager flex | |
1-direction S0 meter |
|
|
bidirectional S0-meter |
|
|
*) Can only be used in conjunction with a Digital Extension.
Number of connectable meters
Quantity | |||
---|---|---|---|
EnergyManager pro without Digital Extension | EnergyManager pro with Digital Extension | Manager flex | |
S0 meter as energy meter | 2 | 8 | 2 |
S0 meter as generation meter (inverter replacement) | 2 | 8 | 1 |
Tested meter types
The following meter types have been tested for faultless operation on the SOLARWATT Managers. Other makes may be usable without restriction. The list only shows the devices tested by SOLARWATT.
- SOLARWATT EnergyMeter (3-phase)
- SOLARWATT Manager meter 1-phase
- B+G DRS155D (1-phase)
- KDK PRO380-S (3-phase, 2-direction meter)
- Eltako DSZ15D (Not compatible with Digital Extension)
- Eltako DSZ15DE (Not compatible with Digital Extension)
The Eastron SDM630 MCT is not compatible with the EnergyManager pro or SOLARWATT Manager flex.