Connect devices

Overview of supported devices
Table of contents

    Full compatibility

    With restrictions

    In release check

    No compatibility

    Inverter

    Fronius

    EnergyManager proManager flex
    Primo (3.0 - 8.2)

    Symo (3.0 - 20.0)

    Symo Advanced

    ECO

    Primo / Symo GEN 24

    Primo / Symo GEN 24 plus
    [hybrid system]

    SMA

    EnergyManager proManager flex
    Sunny Boy (1.5 -6.0)

    Sunny Tripower (3.0 - 10.0)

    Sunny Tripower (15000 - 25000) TL

    Sunny Tripower (5.0-10.0) -3SE-40
    [Hybrid system]

    Sunny Tripower X
    (12 - 25)

    Sunny Tripower CORE1

    Sunny Tripower CORE2

    Sunny Tripower X
    (12 - 25)
    Curtailment (limitation of the feed-in-power) via the SOLARWATT Manager is currently not possible.
    Sunny Tripower CORE1 /2The connection of this device type is currently undergoing approval testing. Until these tests have been completed, perfect function on the Manager flex cannot be guaranteed.

    KACO

    energyManager proManager flex
    blueplanet NX3 M2 (3.0 - 20.0)

    blueplanet NX3 M3 (25.0 - 33.0)

    Kostal

    EnergyManager pro Manager flex
    PLENTICORE plus (3.0 - 10)

    PIKO IQ (3.0 - 10)

    PIKO MP plus

    PIKO CI

    PIKO (12 - 20)

    Steca / Kontron Solar

    EnergyManager pro Manager flex
    StecaGrid coolcept fleX XL (4213 - 10013)

    StecaGrid coolcept fleX (1511 - 3611)

    StecaGrid coolcept3 fleX (3213 - 6013)

    StecaGrid coolcept fleX (3011 - 5011)_2

    SolBrid

    Huawei

    EnergyManager pro Manager flex
    SUN2000
    -2/3/3.68/4/4.6/5/6KTL-L1*

    SUN2000
    -3/4/5/6/8/10KTL-M1
    (high-current version)*

    *) Hybrid system with LUNA2000-5/10/15-S0 battery system possible. Additional component required for integration into the energy management system: Smart Dongle WiFi-FE

    SUN2000
    -2/3/3.68/4/4.6/5/6KTL-L1
    Unknown error; the device cannot be installed under the current Manager flex firmware. The problem is under investigation.

    SolarEdge

    EnergyManager pro Manager flex
    SolarEdge

    Restrictions

    SolarEdgePermanent error message in the Installer Center "NoPowerACOutMax" (cannot be acknowledged)
    SolarEdgeConnection problems may occur when using inverter firmware 004.019 and 004.020. The problem is being investigated. The use of an external meter to record the inverter power is recommended. See Incompatible inverters

    Incompatible inverters

    The power is recorded via separate power meters or energy meters. Depending on the Manager hardware used, different types of meters can be used for performance recording.

    There are also differences in the number of meters that can be configured as generation meters.

    Meter typeNumber of meters that can be configured as generation meters
    EnergyManager proManager flex
    S0 meter*

    2

    1

    Shelly Pro 3EMunlimitedunlimited
    Shelly 3 EMcannot be used as a generation meterunlimited

    Installation instructions can be found under Non-compatible inverters.

    Home battery system

    SOLARWATT

    EnergyManager proManager flex
    Battery flex AC-1

    Battery flex backup solo

    Battery flex DC

    MyReserve Command 25

    MyReserve Command 20.2

    MyReserve 500/800

    VARTA

    EnergyManager proManager flex
    pulse neo

    *

    **

    element S5 backup

    *

    **

    Cascade
    element S5

    *

    **

    Cascade
    pulse neo

    *

    **

    *) Varta Split Core Sensor cannot be used as main meter. The installation of an additional bidirectional meter is required.

    **) Varta Split Core Sensor can be used as main meter.

    Hybrid systems

    The supported hybrid systems are listed under Inverters.

    Wallboxes

    Keba

    EnergyManager proManager flex
    KeContact
    P30
    c-series

    KeContact
    P30
    x-series

    KeContact
    P30
    Dienstwagenwallbox

    KeContact
    P30
    PV Edition

    KeContact
    P30
    a-Series

    KeContact
    P30
    Deutschlandedition

    Webasto

    EnergyManager proManager flex
    liveLAN
    (number of devices*: 1)
    LAN
    (Number of devices*: 1)
    next--LAN, WiFi (via router)
    (number of devices*: 1)

    Alfen

    EnergyManager proManager flex
    Eve Single
    (S-line / Pro Line)

    Restrictions

    Automatic phase switching function not available when installed on EnergyManager pro.

    Possible number of actively controlled wallboxes in the energy management system

    EnergyManager proSOLARWATT Manager flex
    Keba13
    Webasto
    (Live/Next)
    11
    Alfen13

    Shelly devices

    Possible applications

    The various Shelly device types can perform a wide range of tasks in the SOLARWATT energy management system:

    NetworkPossible applications
    EnergyManager proManager flex
    3EMWIFI

    • Measuring/switching SG-Ready heat pump

    • Main meter
    • Energy meter
    • Measuring/switching SG-Ready heat pump
    • Generation meter
      (inverter replacement)
    Pro 3EMWIFI
    LAN
    • Main meter
    • Energy meter
    • Generation meter
      (inverter replacement)
    • Main meter
    • Energy meter
    • Generation meter
      (inverter replacement)
    Pro 3EM 400WIFI
    LAN
    • Main meter
    • Energy meter
    • Generation meter
      (inverter replacement)
    • Main meter
    • Energy meter
    • Generation meter
      (inverter replacement)
    EMWIFI

    • Energy meter
    • Generation meter
      (inverter replacement)

    • Energy meter
    • Generation meter
      (inverter replacement)
    Per 1PM
    Pro 2PM
    Pro 4PM
    WIFI
    LAN
    • Energy meters
    • Measuring/switching consumers
    • Energy meter
    • Measuring/switching consumer
    Plus1PM
    Plus2PM
    WIFI
    • Energy meter
    • Measuring/switching consumer
    • Energy meter
    • Measuring/switching consumers
    Plus Plug S
    Plug S
    WIFI
    • Measuring/switching consumer
    • Measuring/switching consumer
    Shelly 2.5WIFI
    • Energy meter
    • Measuring/switching consumer
    • Energy meter
    • Measuring/switching consumer

    Main meter: Use as bidirectional meter
    Energy meter: Use as single-directional meter

    Network interface and installation location

    shelly devicenetwork interfaceinstallation location
    3EMWIFISwitch cabinet
    Pro 3EMWIFI
    LAN
    Switch cabinet
    Pro 1PM
    Pro 2PM
    Pro 4PM
    WIFI
    LAN
    Switch cabinet
    Plus 1PM
    Plus 2PM
    WIFIFlush-mounted socket
    Plus Plug S
    Plug S
    WIFISchuko socket outlet
    Shelly 2.5WIFIFlush-mounted socket

    myStrom WiFi Switch

    EnergyManager proManager flex
    myStrom WiFi Switch

    Heating solutions

    EnergyManager proManager flex
    Heat pump via
    SG Ready interface

    *

    *

    Stiebel Eltron heat pump
    (thermal energy management)

    Supported types:

    • WPL-A 07 HK 230 Premium
    • WPL 20 A
    • WPL 25 A
    • WPL-A 10 HK 400 Premium
    • WPL-A 13 HK 400 Premium
    • LWZ 304 SOL
    • LWZ 404 SOL
    • LWZ 504
    • LWZ 5 CS Premium
    • LWZ 8 CS Premium

    EGO Smart Heater

    my-PV AC ELWA 2

    my-PV AC THOR 9s

    *) Connection via Shelly 3EM.

    Energy meter / main meter

    Manager flex

    Meter types that can be used with the SOLARWATT Manager flex:

    InterfacePossible applications
    S0 meter*S0
    SOLARWATT
    AC-Sensor

    Ethernet via
    Battery flex /
    MyReserve

    • Main meter
    Shelly devices**Ethernet /
    WiFi
    • Miscellaneous

    *) A total of up to 2 S0 meters can be connected. For more information, see the S0 counter section at the bottom of this page.

    **) See section Shelly devices.

    EnergyManager pro

    Meter types that can be used with the SOLARWATT EnergyManager pro:

    InterfacePossible applications
    S0 meter*S0
    SOLARWATT
    AC-Sensor

    • Ethernet via
      Battery flex /
      MyReserve
    • CAN
    Shelly devices**Ethernet /
    WiFi
    • Miscellaneous
    Janitza
    UMG 103-CBM
    RS485
    • Energy meters
    • Generation meters
    ABB B23RS485
    • Energy meter
    • Generation meter

    *) A total of up to 2 S0 meters can be connected (without digital extension). For more information, see section S0 meters at the bottom of this page.

    ***) See section Shelly devices.

    S0 meters

    S0 meters are electrical energy meters that transmit their meter readings via electrical pulses.

    Meters that deliver pulses in accordance with EN62053-31 can be connected to the SOLARWATT Manager.

    The meters are connected directly, i.e. to the S0 inputs of the SOLARWATT Manager.

    Possible applications

    Possible applications
    EnergyManager proManager flex
    1-direction S0 meter
    • Main meter
      (setup type: grid side PV plants)
    • Energy meter
    • Generation meter
    • Meter for Combined Smart Plug*
    bidirectional S0-meter
    • Main meter
      (Setup type: House-side PV plants)
    • Main meter
      (Setup type: House-side PV plants)

    *) Can only be used in conjunction with a Digital Extension.

    Number of connectable meters

    Quantity
    EnergyManager pro
    without Digital Extension
    EnergyManager pro
    with Digital Extension
    Manager flex
    S0 meter as energy meter282
    S0 meter as generation meter
    (inverter replacement)
    281

    Tested meter types

    The following meter types have been tested for faultless operation on the SOLARWATT Managers. Other makes may be usable without restriction. The list only shows the devices tested by SOLARWATT.

    • SOLARWATT EnergyMeter (3-phase)
    • SOLARWATT Manager meter 1-phase
    • B+G DRS155D (1-phase)
    • KDK PRO380-S (3-phase, 2-direction meter)
    • Eltako DSZ15D (Not compatible with Digital Extension)
    • Eltako DSZ15DE (Not compatible with Digital Extension)

    The Eastron SDM630 MCT is not compatible with the EnergyManager pro or SOLARWATT Manager flex.

    Ripple controller

    EnergyManager proManager flex
    Ripple controller