LEDs and buttons

Description of the LEDs and buttons of the SOLARWATT Manager flex and EnergyManager pro.
Table of contents

    Manager flex

    Front view SOLARWATT Manager flex
    Front view SOLARWATT Manager flex

    Status LED

    DisplayLED FunctionStatus

    Self-testok

    Updaterunning

    Self-testError

    Bootingrunning

    Start not possiblefatal error

    Internet LED

    DisplayFunctionStatus

    Cloud connection
    SOLARWATT Manager portal
    ok

    Cloud connection
    SOLARWATT Manager portal

    Connection to router
    (Internet gateway)

    faulty

    ok

    Connection to the router
    (Internet gateway)
    faulty

    Connection LED

    DisplayFunctionStatus

    Connector to MyReserveok

    Connector to MyReservefaulty

    every 10 sec.PLC connector*Connector established

    every 1 sec.PLC connection*Binding mode

    Setting up a PLC connection: Commissioning and network connection SOLARWATT Manager

    Key functions

    Rear view SOLARWATT Manager flex
    ButtonDescription
    1ConnectResets the network settings
    2InstallEstablishing a PLC connection (data connection via the power grid)
    3Resetreset to factory settings
    4(nameplate)
    5(mounting bracket)

    Resetting the SOLARWATT Manager flex

    Button functionActuation timeFunction
    Install6 secSoft reset
    Local network settings are reset.
    PLC encryption is retained.
    Reset + Install5 secReset factory settings
    Local network settings are reset.
    Devices and their configurations are deleted on the device.
    Binding between SOLARWATT Manager flex and user account is deleted. The user account and the historical data in the SOLARWATT Manager portal are retained.

    Only perform with an active Internet connection, otherwise problems may occur during setup.

    Overview of button functions for Powerline Communication (PLC)

    Button functionActuation timeFunction
    Install3 sec*Activate/ deactivate PLC module**
    Connect6 secPLC connection mode
    Actuation necessary in encrypted PLC networks.
    1 secPLC key exchange
    Necessary in encrypted PLC networks.
    10 secPLC reset
    PLC encryption is reset and connectors are lost.

    *) If the button is pressed for longer, the Manager
    may be reset **) PLC module is deactivated at the factory. Caution: Risk of ring closure in the local network.

    Setting up a PLC connection: Commissioning and network connection SOLARWATT Manager

    EnergyManager pro

    Interfaces for operation

    Device installationEASY button (start of automatic device installation)
    Reset buttonRESET button (restarting the EnergyManager)
    Status LEDDEVICE LED (indicates the general function and a device search)
    Internet connectivityINTERNET LED (Indicates whether the connection to the SOLARWATT Manager portal is established)
    Bus LEDBUS LED (Lights up when the extension bus is active)
    LANConnectivity and transport indicator on the Ethernet connector

    LED codes

    Status LEDDeviceBusInternet status
    OffNo supply voltageNo extension connected-
    GreenGateway (Energy Manager) activeExtension connectedactive, Internet connection available
    Green, flashing (1Hz, slow)Boot process or device search-Boot process
    Green, flashing (10Hz, fast)Update process--
    Orange--Gateway (Energy Manager) was manually set to the maintenance IP, can only be reset by restarting
    Redno device found or installation not successful
    Repeat the process. If the problem persists, consult the online documentation or contact support.
    Problem on the extension bus

    Consult the online documentation or contact support.
    no Internet connection